Goodman Furnace Fault Codes

Goodman furnaces come highly recommended by furnace specialists in Edmonton. The brand is well-built and reliable. But, as with any furnace, Goodman units can experience issues – especially since cold Alberta winters can take such a toll on these types of appliances.
If you run into problems with your Goodman unit, be sure to look for the fault code. Providing furnace error codes to your furnace repair specialist before they arrive will help them solve the issue faster.

Here are some common Goodman furnace fault codes you may come across.

Goodman Furnace Fault CodeMeaningPotential Issue
Light ONNo signal from thermostatThermostat not properly connected, issue with thermostat setting
Light OFFControl failureNo power, issue with connections
1 flashIgnition error (retries exceeded) / Flame failureFaulty or dirty flame sensor, faulty igniter, gas supply interruption, etc.
2 flashesPressure switch error (stuck closed)Short in the pressure switch circuit, faulty pressure switch, draft inducer not working, etc.
3 flashesPressure switch error (stuck open)Blockage in pressure switch hose, pressure switch hose improperly connected, loose wiring, induced draft blower operating when it shouldn’t be, etc.
4 flashesOpen high limitDirty filters, wiring issue, blockage in flue, etc.
5 flashesFlame sensed with gas valve off (i.e. no call for heat)Leaky gas valve, gas valve stuck open, defective flame sensor, etc.
6 flashesOpen rollout switchBlocked or cracked heat exchanger, blocked vent, low gas pressure, etc.
7 flashesLow flame errorLow gas pressure, faulty flame sensor, dirty flame sensor, etc.
8 flashesIgnitor errorFaulty ignitor, ignitor not properly connected, wiring issues, etc.
9 flashesOpen pressure switch, induced draft blower onPressure switch hose cracked, blocked or improperly connected, faulty pressure switch, etc.
Continuous flashingReversed polarityIssue with wiring